← Resource Library

Print this guide

How To: Isolate a Runaway BIB Pump

TROUBLESHOOTING A FLOJET N5000 BIB PUMP

How to: Isolate a Runaway Flojet BIB Pump

There are three lines connected to the pump. The line to be disconnected is the CO2 line.

Swing Hinge Model:

How to: Isolate a Runaway Flojet BIB Pump

Step 1

Turn off the pump.

How to: Isolate a Runaway Flojet BIB Pump

Step 2

Use a screwdriver to loosen the retaining screw.

How to: Isolate a Runaway Flojet BIB Pump

Step 3

Swing the retaining clip to the unlock position.

How to: Isolate a Runaway Flojet BIB Pump

Step 4

Pull down on the brass fitting to remove it.

Slide Lock Model:

How to: Isolate a Runaway Flojet BIB Pump

Step 1

Turn off the pump.

How to: Isolate a Runaway Flojet BIB Pump

Step 2

Slide the retaining clip to the unlock position.

How to: Isolate a Runaway Flojet BIB Pump

Step 3

Pull down on the brass fitting to remove it.

NOTE: If the removed fitting is leaking CO2, turn the CO2 off.

Still need a hand? Call 800-372-5098 or email service@brixbev.com. Our service team, Brix Beverage, keeps Alameda Soda fountains running across the Bay Area.